SIUM System

Metal level measurement system for the CCM mould (SIUM)

Brief system description

The SIUM system is designed to measure the level of molten metal in the moulds of slab and bloom CCMs.
Functions performed by the system:
-        measurement of the metal level in the mould;
-        measurement of the mould flux thickness (with an additional radioisotope metal level sensor installed on the mould);
-        automatic diagnostics of the system operating parameters;
-        output of analogue signals (4-20 mA) proportional to the measured metal level;
-        output of discrete signals characterising the system status;
-        provision of communication with the process control system;
-        recording of process archives. 

Process description

The electromagnetic metal level sensor DUM generates an electrical signal that depends on the degree of filling of the mould with molten metal. The mould position sensor DPK measures the amplitude and frequency of mould oscillation. The signals of the DUM and DPK sensors are filtered and converted into digital form in the MSS-U signal acquisition module and transmitted to the UFO-C metal level measurement controller. In the UFO-C the actual value of the molten metal level in the mould is calculated and transmitted as an analogue current signal or via a digital protocol to the metal control controller. The main system parameters are recorded in a local archive and displayed on the screen of the EWS diagnostics workstation. The hardware structure of the system is shown in the figure below. 
Clipboard02.png


For metal level measurement, either the built-in DUM-B sensor or the portable DUM-M sensor can be used. For slab moulds with a strand width of more than 1500 mm, it is recommended to install a DUM-B consisting of two sensing elements (dual design) symmetrically about the mould centre in order to suppress wave formation on the metal surface. The DPK signal is used when processing the DUM signal to compensate for oscillations caused by mould oscillation. It is permissible to use the mould position signal existing in the process control system without installing the DPK sensor.

Advantages of the proposed system

The air-cooled electromagnetic metal level sensor measures the actual level of liquid steel without taking slag and mould flux into account. When a radioisotope level sensor is used, the measurement error associated with the mould flux is 5-10 mm or more.
Clipboard01.png


The dual design of the level sensor for wide slabs allows the average level of liquid steel to be measured, eliminates the influence of local disturbances and waves on the metal surface on the measured level, and does not react to interference created by metal tools during mould maintenance.
The system can be used as a backup (1 set per CCM) in case of damage or failure of the main system (for example, with a radioisotope sensor). In this case, within a few minutes the system is connected to the corresponding strand and a portable stand-mounted sensor is installed on the mould.

Main technical specifications of the system

Parameter Value
Metal level measurement range in the mould (from the upper edge of the copper mould plates), mm 20-220*
Random component in the output signal (level measurement accuracy) at a liquid metal level of 80 mm, mm ±0.5*
Availability of automatic measurement calibration before casting not required
Long-term measurement stability (slow drift of the output signal) over 8 hours at a liquid metal level of 80 mm, mm, max. ±5*
Absolute error of molten metal level measurement, mm,
max.:
- in the range from 20 to 100 mm
- in the range from 100 to 200 mm
±5*
±10*
Measurement resolution, mm ≤ 0.2*
Measurement time constant, s, max. 0.03
Sensitivity to slag and mould flux none
Compensation of mould oscillation in the output signal yes
AC supply voltage from a single-phase mains 220±10% V
 50/60 Hz
Power consumption (1 strand), W, max. 100